H2O2 (Hydrogen Peroxide) Decontamination-sterilisation pass-through unit FCDV
Sterilisation
We offer a comprehensive range of H2O2 decontamination pass-through sizes to suit your pharmaceutical sterilisation needs.
We offer a comprehensive range of H2O2 decontamination pass-through sizes to suit your pharmaceutical sterilisation needs.This is not just an H2O2 decontamination generator attached to a fumigatable unit.
Our pharmaceutical sterilizers sas H2O2 decontamination are made entirely in stainless steel 316L or 304 for parts in contact with the biocidal agent.The cycle of the H2O2 decontamination chamber is fully controlled by a Thema 4 (GAMP5) industrial computer.
It fully controls the cycle and therefore the humidity of the H2O2 decontamination pass-through's chamber :
Finally, the Thema 4 launches the ventilation of the H2O2 decontamination pass-through to dry the different products and the chamber
Our pharmaceutical sterilizers sas H2O2 decontamination are made entirely in stainless steel 316L or 304 for parts in contact with the biocidal agent.The cycle of the H2O2 decontamination chamber is fully controlled by a Thema 4 (GAMP5) industrial computer.
It fully controls the cycle and therefore the humidity of the H2O2 decontamination pass-through's chamber :
- dehumidification by dry air injection to lower the humidity level from 60% to about 20%
- injection of hydrogen peroxide to achieve an RH of approximately 90%
- maintains stable humidity levels (at the sterilisation plateau). During thiswhole phase the temperature reaches a maximum value of approximately 30-35 ° C.
Finally, the Thema 4 launches the ventilation of the H2O2 decontamination pass-through to dry the different products and the chamber
APPLICATIONS
The H2O2 can be used for the disinfection / sterilisation of surfaces, with different durations depending on the maneuvrability of the materials and the geometric complexity of the loads.
The H2O2 also presents the advantage of having shorter cycles than those generally used for "hot" sterilisation.On average, a cycle lasts 90 minutes.
The biocidal agent is compatible with most materials present in pharmaceutical environments. Only porous materials or some aluminum alloys will need to undergo further attention.
The H2O2 also presents the advantage of having shorter cycles than those generally used for "hot" sterilisation.On average, a cycle lasts 90 minutes.
The biocidal agent is compatible with most materials present in pharmaceutical environments. Only porous materials or some aluminum alloys will need to undergo further attention.
PROCESS
Sterilisation
SERVICES
- IQ / OQ / PQ / FAT / SAT
- After Sales Support
- Training
CHARGES
Cartridges
Equipments
Flasks
Liquid ampoules
PE and PP single dose ampoules
Powders
Syringes
DONNÉES TECHNIQUES
H2O2 Decontamination Pass-through:
Load capacity: from a few hundred liters to several cubic meters
Supply of a pass-through cabin or development of an H2O2 decontamination pass-through tailored to your needs
Pass-through cabins / WxHxD (example): 100mm x 2100mm x 2500mm
Generator: External or integrated
Loop : Open or closed
Control: GAMP 5 system 21 CFR part 11
Load capacity: from a few hundred liters to several cubic meters
Supply of a pass-through cabin or development of an H2O2 decontamination pass-through tailored to your needs
Pass-through cabins / WxHxD (example): 100mm x 2100mm x 2500mm
Generator: External or integrated
Loop : Open or closed
Control: GAMP 5 system 21 CFR part 11